Wróć do katalogu CVE
CVE-2018-7797

Luka umożliwiająca przekierowanie adresu URL w Power Monitoring Expert i Energy Expert

Schneider Electric SE Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxureª Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxureª Energy Expert 1.3 (formerly Power Manager), EcoStruxureª Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxureª Power Monitoring Expert (PME) v9.0, EcoStruxureª Energy Expert v2.0, and EcoStruxureªPower SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module

W skrócie

Luka umożliwiająca przekierowanie adresu URL istnieje w Power Monitoring Expert, Energy Expert (dawniej Power Manager) – EcoStruxure Power Monitoring Expert (PME) w wersji 8.2 (wszystkie wydania), EcoStruxure Energy Expert 1.3 (dawniej Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) w wersji 9.0, EcoStruxure Energy Expert w wersji 2.0 oraz EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module, która może spowodować atak phishingowy po przekierowaniu do złośliwej witryny.

Opis źródłowy · CVE List / CNA

Wpływ na system

Złożoność atakuNiska
PoufnośćNiski
IntegralnośćNiski
DostępnośćBrak

Podsumowanie CVSS v3.0

6.1Średnia
Opublikowano:
Zaktualizowano:
EPSS:
0,755%
Wykorzystanie w atakach:
Niepotwierdzone
Kampanie ransomware:
Niepotwierdzone
Wektor ataku:
Sieć

Podatne produkty

Producent, produkt i zakres podatnych wersji.

Producent, produkt i podatne wersje
Producent:Schneider Electric SEPower Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxureª Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxureª Energy Expert 1.3 (formerly Power Manager), EcoStruxureª Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxureª Power Monitoring Expert (PME) v9.0, EcoStruxureª Energy Expert v2.0, and EcoStruxureªPower SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards ModulePodatne wersje:
EcoStruxure&#xaaPokaż pełny zakres wersji produktu Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxureª Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxureª Energy Expert 1.3 (formerly Power Manager), EcoStruxureª Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxureª Power Monitoring Expert (PME) v9.0, EcoStruxureª Energy Expert v2.0, and EcoStruxureªPower SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module
Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure&#xaaEnergy Expert 1.3 (formerly Power Manager), EcoStruxure&#xaaPower SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure&#xaaPower Monitoring Expert (PME) v9.0, EcoStruxure&#xaaEnergy Expert v2.0, and EcoStruxure&#xaaPower SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module
Producent:schneider-electricecostruxure energy expertPodatne wersje:
1.3Pokaż pełny zakres wersji produktu ecostruxure energy expert
2.0
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Producent:schneider-electricecostruxure power monitoring expertPodatne wersje:
8.2Pokaż pełny zakres wersji produktu ecostruxure power monitoring expert
9.0
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Producent:schneider-electricecostruxure power scada operationPodatne wersje:
8.2Pokaż pełny zakres wersji produktu ecostruxure power scada operation
9.0
  • CPE applicability can depend on other products or environments. Consult the full source configuration.

1–4 z 4 · Strona 1 z 1

Oceny i parametry CVSS2
[email protected] · NVD (Primary)Główna6.1 / 10ŚredniaCVSS 3.0Szczegóły
Złożoność ataku
Niska
Poufność
Niski
Integralność
Niski
Dostępność
Brak
Wektor ataku
Sieć
Uprawnienia
Niewymagane
Udział użytkownika
Wymagany
Zakres wpływu
Zmieniony

Wektor źródłowy

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
[email protected] · NVD (Primary)5.8 / 10ŚredniaCVSS 2.0Szczegóły
Złożoność ataku
Średnia
Poufność
Częściowy
Integralność
Częściowy
Dostępność
Brak
Wektor ataku
Sieć
Uwierzytelnienie
Niewymagane

Wektor źródłowy

AV:N/AC:M/Au:N/C:P/I:P/A:N

CVSS opisuje dotkliwość, EPSS — prawdopodobieństwo wykorzystania. Brak potwierdzenia ataków nie oznacza braku zagrożenia.

Źródła i komunikaty5

This product uses the NVD API but is not endorsed or certified by the NVD. CVE® records © The MITRE Corporation, reproduced under the CVE Terms of Use. Źródła danych i licencje