Rockwell Automation MicroLogix 1100 Incorrect Permission Assignment
Not specified Rockwell Automation MicroLogix 1100 and 1400
At a glance
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.
Source description · CVE List / CNA
System impact
CVSS summary v3.0
- Published:
- Updated:
- EPSS:
- 2.446%
- Exploited in attacks:
- Not confirmed
- Ransomware campaigns:
- Not confirmed
- Attack vector:
- Network
Related CWE
Affected software
Vendor, product and affected version ranges.
| Vendor | Product | Affected versions |
|---|---|---|
| Vendor:Not specified | Rockwell Automation MicroLogix 1100 and 1400 | Affected versions: Rockwell Automation MicroLogix 1100 and 1400 |
| Vendor:rockwellautomation | 1763-l16awa series a | Affected versions:≤ 14.000Show full version range for 1763-l16awa series a
|
| Vendor:rockwellautomation | 1763-l16awa series b | Affected versions:≤ 14.000Show full version range for 1763-l16awa series b
|
| Vendor:rockwellautomation | 1763-l16bbb series a | Affected versions:≤ 14.000Show full version range for 1763-l16bbb series a
|
| Vendor:rockwellautomation | 1763-l16bbb series b | Affected versions:≤ 14.000Show full version range for 1763-l16bbb series b
|
| Vendor:rockwellautomation | 1763-l16bwa series a | Affected versions:≤ 14.000Show full version range for 1763-l16bwa series a
|
| Vendor:rockwellautomation | 1763-l16bwa series b | Affected versions:≤ 14.000Show full version range for 1763-l16bwa series b
|
| Vendor:rockwellautomation | 1763-l16dwd series a | Affected versions:≤ 14.000Show full version range for 1763-l16dwd series a
|
| Vendor:rockwellautomation | 1763-l16dwd series b | Affected versions:≤ 14.000Show full version range for 1763-l16dwd series b
|
| Vendor:rockwellautomation | 1766-l32awa series a | Affected versions:≤ 15.004Show full version range for 1766-l32awa series a
|
1–10 of 21 · Page 1 of 3
CVSS scores and metrics2
[email protected] · NVD (Primary)Primary2.7 / 10LowCVSS 3.0Details
- Attack complexity
- Low
- Confidentiality
- None
- Integrity
- None
- Availability
- Low
- Attack vector
- Network
- Privileges required
- High
- User interaction
- Not required
- Scope
- Unchanged
Source vector
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L[email protected] · NVD (Primary)4.0 / 10MediumCVSS 2.0Details
- Attack complexity
- Low
- Confidentiality
- None
- Integrity
- None
- Availability
- Partial
- Attack vector
- Network
- Authentication
- Single
Source vector
AV:N/AC:L/Au:S/C:N/I:N/A:PCVSS measures severity; EPSS estimates exploitation probability. Lack of confirmed attacks does not mean lack of risk.
Sources and advisories5
This product uses the NVD API but is not endorsed or certified by the NVD. CVE® records © The MITRE Corporation, reproduced under the CVE Terms of Use. Data sources and licences