Denial of service in multiple SIMATIC products via PROFINET DCP packets
Siemens AG Primary Setup Tool (PST)
At a glance
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
Source description · CVE List / CNA
System impact
CVSS summary v3.0
- Published:
- Updated:
- EPSS:
- 0.469%
- Exploited in attacks:
- Not confirmed
- Ransomware campaigns:
- Not confirmed
- Attack vector:
- Adjacent
Related CWE
Affected software
Vendor, product and affected version ranges.
| Vendor | Product | Affected versions |
|---|---|---|
| Vendor:Siemens AG | Primary Setup Tool (PST) | Affected versions: All versions < V4.2 HF1 |
| Vendor:Siemens AG | SIMATIC Automation Tool | Affected versions: All versions < V3.0 |
| Vendor:Siemens AG | SIMATIC NET PC-Software | Affected versions: All versions < V14 SP1 |
| Vendor:Siemens AG | SIMATIC PCS 7 V8.1 | Affected versions: All versions |
| Vendor:Siemens AG | SIMATIC PCS 7 V8.2 | Affected versions: All versions < V8.2 SP1 |
| Vendor:Siemens AG | SIMATIC STEP 7 (TIA Portal) V13 | Affected versions: All versions < V13 SP2 |
| Vendor:Siemens AG | SIMATIC STEP 7 (TIA Portal) V14 | Affected versions: All versions < V14 SP1 |
| Vendor:Siemens AG | SIMATIC STEP 7 V5.X | Affected versions: All versions < V5.6 |
| Vendor:Siemens AG | SIMATIC WinAC RTX 2010 SP2 | Affected versions: All versions |
| Vendor:Siemens AG | SIMATIC WinAC RTX F 2010 SP2 | Affected versions: All versions |
1–10 of 38 · Page 1 of 4
CVSS scores and metrics2
[email protected] · NVD (Primary)Primary6.5 / 10MediumCVSS 3.0Details
- Attack complexity
- Low
- Confidentiality
- None
- Integrity
- None
- Availability
- High
- Attack vector
- Adjacent
- Privileges required
- Not required
- User interaction
- Not required
- Scope
- Unchanged
Source vector
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H[email protected] · NVD (Primary)6.1 / 10MediumCVSS 2.0Details
- Attack complexity
- Low
- Confidentiality
- None
- Integrity
- None
- Availability
- Complete
- Attack vector
- Adjacent
- Authentication
- Not required
Source vector
AV:A/AC:L/Au:N/C:N/I:N/A:CCVSS measures severity; EPSS estimates exploitation probability. Lack of confirmed attacks does not mean lack of risk.