Back to CVE catalog
CVE-2018-7232

Command execution vulnerability in Pelco Sarix Professional

Schneider Electric SE Pelco Sarix Professional

At a glance

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

Source description · CVE List / CNA

System impact

Attack complexityLow
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh

CVSS summary v3.1

9.8Critical
Published:
Updated:
EPSS:
2.049%
Exploited in attacks:
Not confirmed
Ransomware campaigns:
Not confirmed
Attack vector:
Network

Affected software

Vendor, product and affected version ranges.

Vendor, product and affected versions
Vendor:Schneider Electric SEPelco Sarix ProfessionalAffected versions:
all firmware versions prior to 3.29.72
Vendor:schneider-electricimp319-1e firmwareAffected versions:
< 3.29.67Show full version range for imp319-1e firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp519-1e firmwareAffected versions:
< 3.29.67Show full version range for imp519-1e firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp319-1 firmwareAffected versions:
< 3.29.67Show full version range for imp319-1 firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp519-1 firmwareAffected versions:
< 3.29.67Show full version range for imp519-1 firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimps110-1er firmwareAffected versions:
< 3.29.67Show full version range for imps110-1er firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp519-1er firmwareAffected versions:
< 3.29.67Show full version range for imp519-1er firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp1110-1er firmwareAffected versions:
< 3.29.67Show full version range for imp1110-1er firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricimp219-1er firmwareAffected versions:
< 3.29.67Show full version range for imp219-1er firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:schneider-electricibp1110-1er firmwareAffected versions:
< 3.29.67Show full version range for ibp1110-1er firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.

1–10 of 21 · Page 1 of 3

CVSS scores and metrics2
[email protected] · NVD (Primary)Primary9.8 / 10CriticalCVSS 3.1Details
Attack complexity
Low
Confidentiality
High
Integrity
High
Availability
High
Attack vector
Network
Privileges required
Not required
User interaction
Not required
Scope
Unchanged

Source vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
[email protected] · NVD (Primary)7.5 / 10HighCVSS 2.0Details
Attack complexity
Low
Confidentiality
Partial
Integrity
Partial
Availability
Partial
Attack vector
Network
Authentication
Not required

Source vector

AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS measures severity; EPSS estimates exploitation probability. Lack of confirmed attacks does not mean lack of risk.

Sources and advisories4