Back to CVE catalog
CVE-2018-9079

DOM modification and script injection on Iomega, Lenovo, LenovoEMC NAS devices

Lenovo Group LTD Iomega StorCenter

At a glance

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, adversaries can craft URLs to modify the Document Object Model (DOM) of the page. In addition, adversaries can inject HTML script tags and HTML tags with JavaScript handlers to execute arbitrary JavaScript with the origin of the device.

Source description · CVE List / CNA

System impact

Attack complexityLow
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh

CVSS summary v3.0

9.8Critical
Published:
Updated:
EPSS:
1.235%
Exploited in attacks:
Not confirmed
Ransomware campaigns:
Not confirmed
Attack vector:
Network

Affected software

Vendor, product and affected version ranges.

Vendor, product and affected versions
Vendor:Lenovo Group LTDIomega StorCenterAffected versions:
≥ 4.1.402.34662, ≤ 4.1.402.34662
Vendor:Lenovo Group LTDLenovoEMCAffected versions:
≥ 4.1.402.34662, ≤ 4.1.402.34662
Vendor:Lenovo Group LTDEZ Media and Backup CenterAffected versions:
≥ 4.1.402.34662, ≤ 4.1.402.34662
Vendor:lenovopx12-450r firmwareAffected versions:
4.1.402.34662Show full version range for px12-450r firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovostorcenter px12-450r firmwareAffected versions:
4.1.402.34662Show full version range for storcenter px12-450r firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovopx12-400r firmwareAffected versions:
4.1.402.34662Show full version range for px12-400r firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovostorcenter ix2 firmwareAffected versions:
4.1.402.34662Show full version range for storcenter ix2 firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovostorcenter px4-300d firmwareAffected versions:
4.1.402.34662Show full version range for storcenter px4-300d firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovoez media & backup center firmwareAffected versions:
4.1.402.34662Show full version range for ez media & backup center firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.
Vendor:lenovostorcenter px6-300d firmwareAffected versions:
4.1.402.34662Show full version range for storcenter px6-300d firmware
  • CPE applicability can depend on other products or environments. Consult the full source configuration.

1–10 of 23 · Page 1 of 3

CVSS scores and metrics2
[email protected] · NVD (Primary)Primary9.8 / 10CriticalCVSS 3.0Details
Attack complexity
Low
Confidentiality
High
Integrity
High
Availability
High
Attack vector
Network
Privileges required
Not required
User interaction
Not required
Scope
Unchanged

Source vector

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
[email protected] · NVD (Primary)7.5 / 10HighCVSS 2.0Details
Attack complexity
Low
Confidentiality
Partial
Integrity
Partial
Availability
Partial
Attack vector
Network
Authentication
Not required

Source vector

AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS measures severity; EPSS estimates exploitation probability. Lack of confirmed attacks does not mean lack of risk.

Sources and advisories4

This product uses the NVD API but is not endorsed or certified by the NVD. CVE® records © The MITRE Corporation, reproduced under the CVE Terms of Use. Data sources and licences