Back to CVE catalog
CVE-2026-5259

Server-side request forgery in AutohomeCorp frostmourne

AutohomeCorp frostmourne

At a glance

A vulnerability was determined in AutohomeCorp frostmourne up to 1.0. The affected element is an unknown function of the file frostmourne-monitor/src/main/java/com/autohome/frostmourne/monitor/controller/AlarmController.java of the component Alarm Preview. Executing a manipulation can lead to server-side request forgery. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.

Source description · CVE List / CNA

System impact

Attack complexityLow
ConfidentialityLow
IntegrityLow
AvailabilityLow

CVSS summary v4.0

5.3Medium
Published:
Updated:
EPSS:
0.214%
Exploited in attacks:
Not confirmed
Ransomware campaigns:
Not confirmed
Attack vector:
Network

Affected software

Vendor, product and affected version ranges.

Vendor, product and affected versions
Vendor:AutohomeCorpfrostmourneAffected versions:
1.0

1–1 of 1 · Page 1 of 1

CVSS scores and metrics7
VulDB · CVE List / CNA (cna)Primary5.3 / 10MediumCVSS 4.0Details
Attack complexity
Low
Confidentiality
Low
Integrity
Low
Availability
Low
Attack vector
Network
Privileges required
Low
User interaction
Not required
Attack requirements
None
Subsequent confidentiality
None
Subsequent integrity
None
Subsequent availability
None

Source vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
[email protected] · NVD (Secondary)2.1 / 10LowCVSS 4.0Details
Attack complexity
Low
Confidentiality
Low
Integrity
Low
Availability
Low
Attack vector
Network
Privileges required
Low
User interaction
Not required
Attack requirements
None
Subsequent confidentiality
None
Subsequent integrity
None
Subsequent availability
None

Source vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
VulDB · CVE List / CNA (cna)6.3 / 10MediumCVSS 3.1Details
Attack complexity
Low
Confidentiality
Low
Integrity
Low
Availability
Low
Attack vector
Network
Privileges required
Low
User interaction
Not required
Scope
Unchanged

Source vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
[email protected] · NVD (Secondary)6.3 / 10MediumCVSS 3.1Details
Attack complexity
Low
Confidentiality
Low
Integrity
Low
Availability
Low
Attack vector
Network
Privileges required
Low
User interaction
Not required
Scope
Unchanged

Source vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VulDB · CVE List / CNA (cna)6.3 / 10MediumCVSS 3.0Details
Attack complexity
Low
Confidentiality
Low
Integrity
Low
Availability
Low
Attack vector
Network
Privileges required
Low
User interaction
Not required
Scope
Unchanged

Source vector

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
VulDB · CVE List / CNA (cna)6.5 / 10MediumCVSS 2.0Details
Attack complexity
Low
Confidentiality
Partial
Integrity
Partial
Availability
Partial
Attack vector
Network
Authentication
Single

Source vector

AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
[email protected] · NVD (Secondary)6.5 / 10MediumCVSS 2.0Details
Attack complexity
Low
Confidentiality
Partial
Integrity
Partial
Availability
Partial
Attack vector
Network
Authentication
Single

Source vector

AV:N/AC:L/Au:S/C:P/I:P/A:P

CVSS measures severity; EPSS estimates exploitation probability. Lack of confirmed attacks does not mean lack of risk.

Sources and advisories7

This product uses the NVD API but is not endorsed or certified by the NVD. CVE® records © The MITRE Corporation, reproduced under the CVE Terms of Use. Data sources and licences